H2-CNI 0-10V-I

Features:

• Accurate detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air

• No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide

• Fast response and recovery times

• No humidity-induced base line drift

• Applicable in relative humidity (rh) between 0 % to 100 %

• Industrial temperature range from -40 to +80 °C

• High mechanical stability

• Linear output up to 100 % LEL

• On-board instrumentation amplifier and voltage output

• I2C connectivity for sensor adjustment

• Supply voltage with reversed bias protection

• Designed for many years of operation time

H2-CNI 0-10V-I is a pin compatible replacement of previous models H2-CNI-0V-I, H2-CNI 0V-I ULTD, H2-CNI 0V WR sensors. It is a precise calorimetric hydrogen sensor with a catalytically highly active and siloxane-resistant sensor element and is based on a non-isothermal calorimetric operation principle. It contains on-board electronics to reduce the effect of ambient temperature changes on hydrogen sensitivity and to provide appropriate output signals. It is equipped with an additional I2C bus socket and a 0-10V output (like H2-CNI 0V WR). It is designed for use in a variety of applications which require accurate hydrogen determination in air. The sensor can be operated without connecting the I2C bus. 

Pin 1 (red marking) +12 V positive supply voltage with respect to ground 

Pin 2   Sensor signal with respect to ground 

Pin 3   Ground of the internal electronics. The pin is electrically not connected to the housing  

SCL    Serial clock line of I2C bus, referenced to ground (pin 3)* 

SDA    Serial data line of I2C bus, referenced to ground (pin 3)*  



*The sensor can be operated without connecting the I2C 

bus. If connected, provide necessary pull-up resistors to 